PV-Anlage --- Boehl-Nord --- 72,900 kWp --- Stand 10.07.25-22:45:00 | ||
---|---|---|
aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
PV-Monitoring --- (c) pvmoni --- V1.74 2024-06-20 days_htm.php | ||
Erstellt am 10.07.25-22:46 | - Files='days.js + base_vars.js + min_cur.js' - |
#41 --- PV-Boehl-Nord --- '25-07-10/22:45:00' --- Übersicht Datenlogger SMA | |||||
PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
Boehl-Nord | 25-07-10/22:45:00 | SMA-WebBox | 150022412 | 1.53 - | 93 ... 96 ... 98 % |
Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
44.44 | 0 | 0 | 0 | 0 | - |
PV-Boehl-Nord --- '25-07-10/22:45:00' --- aktuelle Wechselrichter-Werte ---Datum---'25_07_10/22:46:51'--- | ||||||||||||||||||||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | #15 | #16 | #17 | #18 | #19 | #20 | #21 | #22 | #23 | ||
WR | DC-A | DC-B | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | DC-A | DC-B | Ertrag | Riso | Status | Fehler | Total (vom WR) | Total-vTag | Total-12.24 | 2025 | 2025 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||
Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | Wp | Wp | kWh/kWp | kOhm | #8 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||
WR-01 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 63.484 | 12.150 | 6.075 | 6.075 | 5,23 | 0 | ? | - | 154.562.422 | 154.498.938 | 148.726 | 5.836 | 480,3 | 0 | 154.562 | 12.721 | -2.5 % | -3.942 kWh | -324 kWh/kWp | ||
WR-02 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 66.888 | 12.150 | 6.075 | 6.075 | 5,51 | 0 | ? | - | 154.037.052 | 153.970.164 | 147.938 | 6.099 | 502 | 0 | 154.037 | 12.678 | -2.8 % | -4.467 kWh | -367 kWh/kWp | ||
WR-03 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 64.842 | 12.150 | 6.075 | 6.075 | 5,34 | 0 | ? | - | 157.394.575 | 157.329.733 | 151.445 | 5.949 | 489,6 | 0 | 157.395 | 12.954 | -0.7 % | -1.110 kWh | -91 kWh/kWp | ||
WR-04 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 63.486 | 12.150 | 6.075 | 6.075 | 5,23 | 0 | ? | - | 154.297.691 | 154.234.205 | 148.521 | 5.777 | 475,5 | 0 | 154.298 | 12.699 | -2.7 % | -4.206 kWh | -346 kWh/kWp | ||
WR-05 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 67.001 | 12.150 | 6.075 | 6.075 | 5,51 | 0 | ? | - | 1.416.574 | 1.349.573 | 86.545 | -85.128 | -7006,45 | 0 | 1.417 | 116,6 | -99.1 % | -157.024 kWh | -12929 kWh/kWp | ||
WR-06 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 65.092 | 12.150 | 6.075 | 6.075 | 5,36 | 0 | ? | - | 158.504.654 | 158.439.562 | 152.545 | 5.960 | 490,5 | 0 | 158.505 | 13.046 | bester WR mit 100% | ||
SUMME | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 390.793 | 72.900 | 36.450 | 36.450 | 5,36 | Riso | - | - | 780.212.968 | 779.822.175 | 835.720 | -55.508 | -761,42 | 0 | 780.213 | 10.703 | Summe 170.749 kWh |
PV-Boehl-Nord --- '25-07-10/22:45:00' --- WR_Beschreibung / SN | ||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 |
WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
Nr | Typ | Nummer | Name | Wp | Wp | Wp |
WR-01 | SMA-11000TL | WR11TL08:2000783687 | WR-1 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-02 | SMA-11000TL | WR11TL09:2000943168 | WR-2 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-03 | SMA-11000TL | WR11TL08:2000781246 | WR-3 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-04 | SMA-11000TL | WR11TL08:2000780947 | WR-4 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-05 | SMA-11000TL | WR11TL08:2001180813 | WR-5 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-06 | SMA-11000TL | WR11TL08:2000798925 | WR-6 | S1=6.075 | S2=6.075 | 12.150 Wp |
SUMME | ||||||
Sum-Wp | 36.450 Wp | 36.450 Wp | 72.900 Wp |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Status-Tabelle ( #8 Werte) |
0='Undetermined' |
1='NoConnection' |
2='Online' |
3='Msg' |
4='MPP' |
5='Fault' |
6='Warning' |
7='Off' |
8='Unknown' |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Fehler-Tabelle ( #60 Werte) |
1='Frequency not permitted' |
2='Derating occurred' |
3='Unstable operation' |
4='Data storage not possible' |
5='Insulation resistance' |
6='Grid failure' |
7='-------' |
8='Communication disturbed' |
9='DC overcurrent' |
10='Overload' |
11='Overtemperature' |
12='Varistor defective' |
13='Start conditions not met' |
14='PE connection missing' |
15='L / N swapped' |
16='DC overvoltage' |
17='Interference of device' |
18='Check fuse' |
19='Check generator' |
20='Disconnect generator' |
21='Check parameter' |
22='Check connection' |
23='High discharge current' |
24='SD card defective' |
25='Parameter file error' |
26='Set parameter' |
27='Parameter setting failed' |
28='Parameters set successfully' |
29='No new update on the SD card' |
30='Update file defective' |
31='Update file OK' |
32='No update file found' |
33='Self diagnosis' |
34='self-test' |
35='Abort self-test' |
36='Input A defective' |
37='Input B defective' |
38='Grid parameter unchanged' |
39='Grid parameter locked' |
40='Installer code invalid' |
41='Sens. fault fan permanently on' |
42='Installer code valid' |
43='Update Bluetooth' |
44='Update Bluetooth failed' |
45='SD card is read' |
46='Update completed' |
47='Update main CPU' |
48='Update main CPU failed' |
49='Update RS485I module' |
50='Update RS485I module failed' |
51='Update communication' |
52='Update language table' |
53='Update language table failed' |
54='Update display' |
55='Update display failed' |
56='Wait for DC start conditions' |
57='Waiting for grid voltage' |
58='Residual current too high' |
59='Installation fault' |
60='Change grid param. impossible' |