| PV-Anlage --- Boehl-Nord --- 72,900 kWp --- Stand 27.07.26-22:45:00 | ||
|---|---|---|
| aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
| PV-Monitoring --- (c) pvmoni --- V1.76 2026-07-27 days_htm.php | ||
| Erstellt am 27.07.26-22:48 | - Files='days.js + base_vars.js + min_cur.js' - | |
| #69 --- PV-Boehl-Nord --- '26-07-27/22:45:00' --- Übersicht Datenlogger SMA | |||||
| PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
| Boehl-Nord | 26-07-27/22:45:00 | SMA-WebBox | 150022412 | 1.53 - | 93 ... 96 ... 98 % |
| Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
| 44.44 | 0 | 0 | 0 | 0 | - |
| PV-Boehl-Nord --- '26-07-27/22:45:00' --- aktuelle Wechselrichter-Werte ---Datum---'26_07_27/22:48:35'--- | ||||||||||||||||||||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | #15 | #16 | #17 | #18 | #19 | #20 | #21 | #22 | #23 | ||
| WR | DC-A | DC-B | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | DC-A | DC-B | Ertrag | Riso | Status | Fehler | Total (vom WR) | Total-vTag | Total-12.25 | 2026 | 2026 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||
| Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | Wp | Wp | kWh/kWp | kOhm | #8 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||
| WR-01 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 33.112 | 12.150 | 6.075 | 6.075 | 2,73 | 0 | ? | - | 164.719.012 | 164.685.900 | 158.141 | 6.578 | 541 | 0 | 164.719 | 13.557 | -2.5 % | -4.177 kWh | -343 kWh/kWp | ||
| WR-02 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 34.538 | 12.150 | 6.075 | 6.075 | 2,84 | 0 | ? | - | 164.653.453 | 164.618.915 | 157.769 | 6.884 | 567 | 0 | 164.653 | 13.552 | -2.5 % | -4.243 kWh | -349 kWh/kWp | ||
| WR-03 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 33.847 | 12.150 | 6.075 | 6.075 | 2,79 | 0 | ? | - | 167.755.986 | 167.722.139 | 161.046 | 6.710 | 552 | 0 | 167.756 | 13.807 | -0.7 % | -1.140 kWh | -93 kWh/kWp | ||
| WR-04 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 33.342 | 12.150 | 6.075 | 6.075 | 2,74 | 0 | ? | - | 164.390.869 | 164.357.527 | 157.842 | 6.549 | 539 | 0 | 164.391 | 13.530 | -2.7 % | -4.506 kWh | -370 kWh/kWp | ||
| WR-05 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 34.911 | 12.150 | 6.075 | 6.075 | 2,87 | 0 | ? | - | 12.085.182 | 12.050.271 | 5.170 | 6.915 | 569 | 0 | 12.085 | 995 | -92.8 % | -156.809 kWh | -12906 kWh/kWp | ||
| WR-06 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 34.077 | 12.150 | 6.075 | 6.075 | 2,80 | 0 | ? | - | 168.896.988 | 168.862.911 | 162.157 | 6.739 | 555 | 0 | 168.897 | 13.901 | bester WR mit 100% | ||
| SUMME | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 203.827 | 72.900 | 36.450 | 36.450 | 2,80 | Riso | - | - | 842.501.490 | 842.297.663 | 802.126 | 40.375 | 554 | 0 | 842.501 | 11.557 | Summe 170.875 kWh | ||
| PV-Boehl-Nord --- '26-07-27/22:45:00' --- WR_Beschreibung / SN | ||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 |
| WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
| Nr | Typ | Nummer | Name | Wp | Wp | Wp |
| WR-01 | SMA-11000TL | WR11TL08:2000783687 | WR-1 | S1=6.075 | S2=6.075 | 12.150 Wp |
| WR-02 | SMA-11000TL | WR11TL09:2000943168 | WR-2 | S1=6.075 | S2=6.075 | 12.150 Wp |
| WR-03 | SMA-11000TL | WR11TL08:2000781246 | WR-3 | S1=6.075 | S2=6.075 | 12.150 Wp |
| WR-04 | SMA-11000TL | WR11TL08:2000780947 | WR-4 | S1=6.075 | S2=6.075 | 12.150 Wp |
| WR-05 | SMA-11000TL | WR11TL08:2001180813 | WR-5 | S1=6.075 | S2=6.075 | 12.150 Wp |
| WR-06 | SMA-11000TL | WR11TL08:2000798925 | WR-6 | S1=6.075 | S2=6.075 | 12.150 Wp |
| SUMME | ||||||
| Sum-Wp | 36.450 Wp | 36.450 Wp | 72.900 Wp | |||
| --- Tabelle für 'SMA'-Wechselrichter |
| SolarLog-Status-Tabelle ( #8 Werte) |
| 0='Undetermined' |
| 1='NoConnection' |
| 2='Online' |
| 3='Msg' |
| 4='MPP' |
| 5='Fault' |
| 6='Warning' |
| 7='Off' |
| 8='Unknown' |
| --- Tabelle für 'SMA'-Wechselrichter |
| SolarLog-Fehler-Tabelle ( #60 Werte) |
| 1='Frequency not permitted' |
| 2='Derating occurred' |
| 3='Unstable operation' |
| 4='Data storage not possible' |
| 5='Insulation resistance' |
| 6='Grid failure' |
| 7='-------' |
| 8='Communication disturbed' |
| 9='DC overcurrent' |
| 10='Overload' |
| 11='Overtemperature' |
| 12='Varistor defective' |
| 13='Start conditions not met' |
| 14='PE connection missing' |
| 15='L / N swapped' |
| 16='DC overvoltage' |
| 17='Interference of device' |
| 18='Check fuse' |
| 19='Check generator' |
| 20='Disconnect generator' |
| 21='Check parameter' |
| 22='Check connection' |
| 23='High discharge current' |
| 24='SD card defective' |
| 25='Parameter file error' |
| 26='Set parameter' |
| 27='Parameter setting failed' |
| 28='Parameters set successfully' |
| 29='No new update on the SD card' |
| 30='Update file defective' |
| 31='Update file OK' |
| 32='No update file found' |
| 33='Self diagnosis' |
| 34='self-test' |
| 35='Abort self-test' |
| 36='Input A defective' |
| 37='Input B defective' |
| 38='Grid parameter unchanged' |
| 39='Grid parameter locked' |
| 40='Installer code invalid' |
| 41='Sens. fault fan permanently on' |
| 42='Installer code valid' |
| 43='Update Bluetooth' |
| 44='Update Bluetooth failed' |
| 45='SD card is read' |
| 46='Update completed' |
| 47='Update main CPU' |
| 48='Update main CPU failed' |
| 49='Update RS485I module' |
| 50='Update RS485I module failed' |
| 51='Update communication' |
| 52='Update language table' |
| 53='Update language table failed' |
| 54='Update display' |
| 55='Update display failed' |
| 56='Wait for DC start conditions' |
| 57='Waiting for grid voltage' |
| 58='Residual current too high' |
| 59='Installation fault' |
| 60='Change grid param. impossible' |