PV-Anlage --- Boehl-Nord --- 72,900 kWp --- Stand 21.10.25-22:45:00 | ||
---|---|---|
aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
PV-Monitoring --- (c) pvmoni --- V1.75 2025-08-19 days_htm.php | ||
Erstellt am 21.10.25-22:51 | - Files='days.js + base_vars.js + min_cur.js' - |
#48 --- PV-Boehl-Nord --- '25-10-21/22:45:00' --- Übersicht Datenlogger SMA | |||||
PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
Boehl-Nord | 25-10-21/22:45:00 | SMA-WebBox | 150022412 | 1.53 - | 93 ... 96 ... 98 % |
Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
44.44 | 0 | 0 | 0 | 0 | - |
PV-Boehl-Nord --- '25-10-21/22:45:00' --- aktuelle Wechselrichter-Werte ---Datum---'25_10_21/22:51:33'--- | ||||||||||||||||||||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | #15 | #16 | #17 | #18 | #19 | #20 | #21 | #22 | #23 | ||
WR | DC-A | DC-B | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | DC-A | DC-B | Ertrag | Riso | Status | Fehler | Total (vom WR) | Total-vTag | Total-12.24 | 2025 | 2025 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||
Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | Wp | Wp | kWh/kWp | kOhm | #8 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||
WR-01 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 13.122 | 12.150 | 6.075 | 6.075 | 1,08 | 0 | ? | - | 157.690.576 | 157.677.454 | 148.726 | 8.964 | 738 | 0 | 157.691 | 12.979 | -2.5 % | -4.026 kWh | -331 kWh/kWp | ||
WR-02 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 13.512 | 12.150 | 6.075 | 6.075 | 1,11 | 0 | ? | - | 157.308.653 | 157.295.141 | 147.938 | 9.371 | 771 | 0 | 157.309 | 12.947 | -2.7 % | -4.407 kWh | -362 kWh/kWp | ||
WR-03 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 13.274 | 12.150 | 6.075 | 6.075 | 1,09 | 0 | ? | - | 160.594.721 | 160.581.447 | 151.445 | 9.149 | 753 | 0 | 160.595 | 13.218 | -0.7 % | -1.121 kWh | -92 kWh/kWp | ||
WR-04 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 13.079 | 12.150 | 6.075 | 6.075 | 1,08 | 0 | ? | - | 157.425.127 | 157.412.048 | 148.521 | 8.904 | 733 | 0 | 157.425 | 12.957 | -2.7 % | -4.291 kWh | -353 kWh/kWp | ||
WR-05 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 13.552 | 12.150 | 6.075 | 6.075 | 1,12 | 0 | ? | - | 4.711.040 | 4.697.488 | 86.545 | -81.834 | -6735,30 | 0 | 4.711 | 387,7 | -97.1 % | -157.004 kWh | -12922 kWh/kWp | ||
WR-06 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 13.189 | 12.150 | 6.075 | 6.075 | 1,09 | 0 | ? | - | 161.716.665 | 161.703.476 | 152.545 | 9.172 | 755 | 0 | 161.717 | 13.310 | bester WR mit 100% | ||
SUMME | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 79.728 | 72.900 | 36.450 | 36.450 | 1,09 | Riso | - | - | 799.446.782 | 799.367.054 | 835.720 | -36.274 | -497,58 | 0 | 799.447 | 10.966 | Summe 170.849 kWh |
PV-Boehl-Nord --- '25-10-21/22:45:00' --- WR_Beschreibung / SN | ||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 |
WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
Nr | Typ | Nummer | Name | Wp | Wp | Wp |
WR-01 | SMA-11000TL | WR11TL08:2000783687 | WR-1 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-02 | SMA-11000TL | WR11TL09:2000943168 | WR-2 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-03 | SMA-11000TL | WR11TL08:2000781246 | WR-3 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-04 | SMA-11000TL | WR11TL08:2000780947 | WR-4 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-05 | SMA-11000TL | WR11TL08:2001180813 | WR-5 | S1=6.075 | S2=6.075 | 12.150 Wp |
WR-06 | SMA-11000TL | WR11TL08:2000798925 | WR-6 | S1=6.075 | S2=6.075 | 12.150 Wp |
SUMME | ||||||
Sum-Wp | 36.450 Wp | 36.450 Wp | 72.900 Wp |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Status-Tabelle ( #8 Werte) |
0='Undetermined' |
1='NoConnection' |
2='Online' |
3='Msg' |
4='MPP' |
5='Fault' |
6='Warning' |
7='Off' |
8='Unknown' |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Fehler-Tabelle ( #60 Werte) |
1='Frequency not permitted' |
2='Derating occurred' |
3='Unstable operation' |
4='Data storage not possible' |
5='Insulation resistance' |
6='Grid failure' |
7='-------' |
8='Communication disturbed' |
9='DC overcurrent' |
10='Overload' |
11='Overtemperature' |
12='Varistor defective' |
13='Start conditions not met' |
14='PE connection missing' |
15='L / N swapped' |
16='DC overvoltage' |
17='Interference of device' |
18='Check fuse' |
19='Check generator' |
20='Disconnect generator' |
21='Check parameter' |
22='Check connection' |
23='High discharge current' |
24='SD card defective' |
25='Parameter file error' |
26='Set parameter' |
27='Parameter setting failed' |
28='Parameters set successfully' |
29='No new update on the SD card' |
30='Update file defective' |
31='Update file OK' |
32='No update file found' |
33='Self diagnosis' |
34='self-test' |
35='Abort self-test' |
36='Input A defective' |
37='Input B defective' |
38='Grid parameter unchanged' |
39='Grid parameter locked' |
40='Installer code invalid' |
41='Sens. fault fan permanently on' |
42='Installer code valid' |
43='Update Bluetooth' |
44='Update Bluetooth failed' |
45='SD card is read' |
46='Update completed' |
47='Update main CPU' |
48='Update main CPU failed' |
49='Update RS485I module' |
50='Update RS485I module failed' |
51='Update communication' |
52='Update language table' |
53='Update language table failed' |
54='Update display' |
55='Update display failed' |
56='Wait for DC start conditions' |
57='Waiting for grid voltage' |
58='Residual current too high' |
59='Installation fault' |
60='Change grid param. impossible' |