| PV-Anlage --- Boehl-Sued --- 103,950 kWp --- Stand 29.10.25-11:00:04 | ||
|---|---|---|
| aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
| PV-Monitoring --- (c) pvmoni --- V1.75 2025-08-19 days_htm.php | ||
| Erstellt am 29.10.25-11:03 | - Files='days.js + base_vars.js + min_cur.js' - | |
| #16 --- PV-Boehl-Sued --- '25-10-29/11:00:04' --- Übersicht Datenlogger SolarLog | |||||
| PV-Anlage | Datum | SolarLog | SerienNr | Firmware | Wirkungsgrad AC / DC |
| Boehl-Sued | 25-10-29/11:00:04 | 1000 | 1616475836 | 2.8.4 Build 56 - 27.01.2014 | 93 ... 96 ... 98 % |
| Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
| 45.11 | 30.389 | 32.048 | 15.692 | 16.356 | - |
| PV-Boehl-Sued --- '25-10-29/11:00:04' --- aktuelle Wechselrichter-Werte ---Datum---'25_10_29/11:03:10'--- | ||||||||||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | |
| WR | DC-A | DC-B | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | DC-A | DC-B | Ertrag | Riso | Status | Fehler | |
| Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | Wp | Wp | kWh/kWp | kOhm | #201 | #72 | |
| WR-01 | 4.587 ( 0,30 ) -7 % | 4.965 ( 0,33 ) | 9.552 ( 0,32 ) | 9.026 ( 0,30 ) | 94.49 % | 20.593 | 30.240 | 15.120 | 15.120 | 0,68 | - | 6=Run=MPP | - | |
| WR-02 | 4.191 ( 0,28 ) -8 % | 4.568 ( 0,30 ) | 8.759 ( 0,29 ) | 8.277 ( 0,27 ) | 94.50 % | 18.928 | 30.240 | 15.120 | 15.120 | 0,63 | - | 6=Run=MPP | - | |
| WR-03 | 4.438 ( 0,29 ) -10 % | 4.972 ( 0,33 ) | 9.410 ( 0,31 ) | 8.892 ( 0,29 ) | 94.50 % | 20.754 | 30.240 | 15.120 | 15.120 | 0,69 | - | 6=Run=MPP | - | |
| WR-04 | 2.476 ( 0,33 ) | 1.851 ( 0,33 ) | 4.327 ( 0,33 ) | 4.194 ( 0,32 ) | 96.93 % | 9.153 | 13.230 | 7.560 | 5.670 | 0,69 | - | 6=Run=MPP | - | |
| SUMME | 15.692 ( 0,30 ) | 16.356 ( 0,32 ) | 32.048 ( 0,31 ) | 30.389 ( 0,29 ) | 94.82 % | 69.428 | 103.950 | 52.920 | 51.030 | 0,67 | Riso | - | - | |
| PV-Boehl-Sued --- '25-10-29/11:00:04' --- WR_Beschreibung / SN | ||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 |
| WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
| Nr | Typ | Nummer | Name | Wp | Wp | Wp |
| WR-01 | PVI-TRIO 27k | 2 | WR-1-30240-432x-900 | S1-24x9x70=216x=15.120 | S2-24x9x70=216x=15.120 | 30.240 Wp |
| WR-02 | PVI-TRIO 27k | 4 | WR-2-30240-432x-821 | S1-24x9x70=216x=15.120 | S2-24x9x70=216x=15.120 | 30.240 Wp |
| WR-03 | PVI-TRIO 27k | 6 | WR-3-30240-432x-815 | S1-24x9x70=216x=15.120 | S2-24x9x70=216x=15.120 | 30.240 Wp |
| WR-04 | PVI-TRIO 20k | 5 | WR4-13230-189x-351 | S1-12x9x70=108x=7.560 | S2-9x9x70=81x=5.670 | 13.230 Wp |
| SUMME | ||||||
| Sum-Wp | 52.920 Wp | 51.030 Wp | 103.950 Wp | |||
| --- Tabelle für 'Power-One'-Wechselrichter |
| SolarLog-Status-Tabelle ( #201 Werte) |
| 0='Sending Parameters' |
| 1='Wait Sun/Grid' |
| 2='Checking Grid' |
| 3='Measuring Riso' |
| 4='DcDc Start' |
| 5='Inverter Start' |
| 6='Run' |
| 7='Recovery' |
| 8='Pause' |
| 9='Ground Fault' |
| 10='OTH Fault' |
| 11='Address Setting' |
| 12='Self Test' |
| 13='Self Test Fail' |
| 14='Sensor Test + Meas.Riso' |
| 15='Leak Fault' |
| 16='Waiting for manual reset' |
| 17='Internal Error E026' |
| 18='Internal Error E027' |
| 19='Internal Error E028' |
| 20='Internal Error E029' |
| 21='Internal Error E030' |
| 22='Sending Wind Table' |
| 23='Failed Sending table' |
| 24='UTH Fault' |
| 25='Remote OFF' |
| 26='Interlock Fail' |
| 27='Executing Autotest' |
| 30='Waiting Sun' |
| 31='Temperature Fault' |
| 32='Fan Staucked' |
| 33='Int. Com. Fault' |
| 34='Slave Insertion' |
| 35='DC Switch Open' |
| 36='TRAS Switch Open' |
| 37='MASTER Exclusion' |
| 38='Auto Exclusion' |
| 42='Waiting' |
| 98=' Erasing Internal EEprom' |
| 99='Erasing External EEprom' |
| 100='Counting EEprom' |
| 101='Freeze' |
| 201='Dsp Programming' |
| --- Tabelle für 'Power-One'-Wechselrichter |
| SolarLog-Fehler-Tabelle ( #72 Werte) |
| 1='Sun Low W001' |
| 2='Input OC E001' |
| 3='Input UV W002' |
| 4='Input OV E002' |
| 5='Sun Low W001' |
| 6='No Parameters E003' |
| 7='Bulk OV E004' |
| 8='Comm.Error E005' |
| 9='Output OC E006' |
| 10='IGBT Sat E007' |
| 11='Bulk UV W011' |
| 12='Internal error E009' |
| 13='Grid Fail W003' |
| 14='Bulk Low E010' |
| 15='Ramp Fail E011' |
| 16='Dc/Dc Fail E012' |
| 17='Wrong Mode E013' |
| 18='Ground Fault ---' |
| 19='Over Temp. E014' |
| 20='Bulk Cap Fail E015' |
| 21='Inverter Fail E016' |
| 22='Start Timeout E017' |
| 23='Ground Fault E018' |
| 24='Degauss error ---' |
| 25='Ileak sens.fail E019' |
| 26='DcDc Fail E012' |
| 27='Self Test Error 1 E020' |
| 28='Self Test Error 2 E021' |
| 29='Self Test Error 3 E019' |
| 30='Self Test Error 4 E022' |
| 31='DC inj error E023' |
| 32='Grid OV W004' |
| 33='Grid UV W005' |
| 34='Grid OF W006' |
| 35='Grid UF W007' |
| 36='Z grid Hi W008' |
| 37='Internal error E024' |
| 38='Riso Low E025' |
| 39='Vref Error E026' |
| 40='Error Meas V E027' |
| 41='Error Meas F E028' |
| 42='Error Meas Z E029' |
| 43='Error Meas Ileak E030' |
| 44='Error Read V E031' |
| 45='Error Read I E032' |
| 46='Table fail W009' |
| 47='Fan Fail W010' |
| 48='UTH E033' |
| 49='Interlock fail E034' |
| 50='Remote Off E035' |
| 51='Vout Avg errror E036' |
| 52='Battery low W012' |
| 53='Clk fail W013' |
| 54='Input UC E037' |
| 55='Zero Power W014' |
| 56='Fan Stucked E038' |
| 57='DC Switch Open E039' |
| 58='Tras Switch Open E040' |
| 59='AC Switch Open E041' |
| 60='Bulk UV E042' |
| 61='Autoexclusion E043' |
| 62='Grid df/dt W015' |
| 63='Den switch Open W016' |
| 64='Jbox fail W017' |
| 65='DC Door Open E044' |
| 66='AC Door Open E045' |
| 67='Module Door Open E047' |
| 68='Fuse DC Fail W020' |
| 69='Liquid Cooler Fail E048' |
| 70='SPD AC protection open W018' |
| 71='SPD DC protection open W019' |
| 72='String selftest fail E046' |