PV-Anlage --- Freckenfeld --- 11,100 kWp --- Stand 05.09.20-16:30:03 ---ERROR Datum--- | ||
---|---|---|
aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
PV-Monitoring --- (c) pvmoni --- V1.67 2022-10-25 days_htm.php | ||
Erstellt am 26.10.22-10:55 | - Files='days.js + base_vars.js + min_cur.js' - |
PV-Freckenfeld --- '20-09-05/16:30:03' --- Übersicht Datenlogger SMA | |||||
PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
Freckenfeld | 20-09-05/16:30:03 | 500 | 540227580 | 2.8.4 Build 56 - 27.01.2014 | 93 ... 96 ... 98 % |
Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-1 [Watt] | DC-2 [Watt] | DC-3 [Watt] |
39.14 | 381 | 398 | 271 | 127 | - |
PV-Freckenfeld --- '20-09-05/16:30:03' --- aktuelle Wechselrichter-Werte ---#2---2022_10_26/10:55:04--- | ||||||||||||||||||||||||
WR | DC-1 | DC-2 | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | DC-1 | DC-2 | Ertrag | Riso | Status | Fehler | Total | Total-vTag | Total-12.21 | 2022 | 2022 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||
Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | Wp | Wp | kWh/kWp | kOhm | #8 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||
WR-01 | 142 ( 0,04 ) | 63 ( 0,03 ) -11 % | 205 ( 0,04 ) | 190 ( 0,03 ) | 92.68 % | 0 | 5.550 | 3.700 | 1.850 | 0,00 | - | 4=MPP | - | 0 | 0 | 0 | 0 | 0,00 | 0 | 0 | 0,00 | -100.0 % | -0 kWh | -0 kWh/kWp | ||
WR-02 | 129 ( 0,03 ) | 64 ( 0,03 ) | 193 ( 0,03 ) | 191 ( 0,03 ) | 98.96 % | 0 | 5.550 | 3.700 | 1.850 | 0,00 | - | 4=MPP | - | 0 | 0 | 0 | 0 | 0,00 | 0 | 0 | 0,00 | -100.0 % | -0 kWh | -0 kWh/kWp | ||
Summe | 271 ( 0,04 ) | 127 ( 0,03 ) | 398 ( 0,04 ) | 381 ( 0,03 ) | 95.73 % | 0 | 11.100 | 7.400 | 3.700 | 0,00 | Riso | - | - | 0 | 0 | 0 | 0 | 0,00 | 0 | 0 | 0,00 | Summe 0 kWh |
PV-Freckenfeld --- '20-09-05/16:30:03' --- Typ-WR | ||||||
WR | WR | SerienNr | WR-Name | DC-1 | DC-2 | DC-3 |
Nr | Typ | - | - | Wp | Wp | Wp |
WR-01 | WR4_5TL-20 | 2100159998 | WR-1 | String-1-1=3.700 Wp | String-1-2=1.850 Wp | - |
WR-02 | WR4_5TL-20 | 2100160988 | WR-2 | String-2-1=3.700 Wp | String-2-2=1.850 Wp | - |
Summe |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Status-Tabelle ( #8 Werte) |
0='Undetermined' |
1='NoConnection' |
2='Online' |
3='Msg' |
4='MPP' |
5='Fault' |
6='Warning' |
7='Off' |
8='Unknown' |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Fehler-Tabelle ( #60 Werte) |
1='Frequency not permitted' |
2='Derating occurred' |
3='Unstable operation' |
4='Data storage not possible' |
5='Insulation resistance' |
6='Grid failure' |
7='-------' |
8='Communication disturbed' |
9='DC overcurrent' |
10='Overload' |
11='Overtemperature' |
12='Varistor defective' |
13='Start conditions not met' |
14='PE connection missing' |
15='L / N swapped' |
16='DC overvoltage' |
17='Interference of device' |
18='Check fuse' |
19='Check generator' |
20='Disconnect generator' |
21='Check parameter' |
22='Check connection' |
23='High discharge current' |
24='SD card defective' |
25='Parameter file error' |
26='Set parameter' |
27='Parameter setting failed' |
28='Parameters set successfully' |
29='No new update on the SD card' |
30='Update file defective' |
31='Update file OK' |
32='No update file found' |
33='Self diagnosis' |
34='self-test' |
35='Abort self-test' |
36='Input A defective' |
37='Input B defective' |
38='Grid parameter unchanged' |
39='Grid parameter locked' |
40='Installer code invalid' |
41='Sens. fault fan permanently on' |
42='Installer code valid' |
43='Update Bluetooth' |
44='Update Bluetooth failed' |
45='SD card is read' |
46='Update completed' |
47='Update main CPU' |
48='Update main CPU failed' |
49='Update RS485I module' |
50='Update RS485I module failed' |
51='Update communication' |
52='Update language table' |
53='Update language table failed' |
54='Update display' |
55='Update display failed' |
56='Wait for DC start conditions' |
57='Waiting for grid voltage' |
58='Residual current too high' |
59='Installation fault' |
60='Change grid param. impossible' |