PV-Anlage --- Freckenfeld --- 11,100 kWp --- Stand 01.07.25-13:10:03
aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter
PV-Monitoring --- (c) pvmoni --- V1.74 2024-06-20 days_htm.php
Erstellt am 01.07.25-13:16 - Files='days.js + base_vars.js + min_cur.js' -

#51 --- PV-Freckenfeld --- '25-07-01/13:10:03' --- Übersicht Datenlogger SolarLog
PV-Anlage Datum SolarLog SerienNr Firmware Wirkungsgrad AC / DC
Freckenfeld 25-07-01/13:10:03 500 540227580 2.8.4 Build 56 - 27.01.2014 93 ... 96 ... 98 %
Vergütung Cent/kWh Sum-AC [Watt] Sum-DC [Watt] DC-A [Watt] DC-B [Watt] DC-C [Watt]
39.14 7.587 7.708 5.233 2.475 -

PV-Freckenfeld --- '25-07-01/13:10:03' --- aktuelle Wechselrichter-Werte ---Datum---'25_07_01/13:16:26'---
#1#2#3#4#5#6#7#8#9#10#11#12#13#14
WR DC-A DC-B DC-Summe AC Wirkungsgrad AC-Ertrag WR DC-A DC-B Ertrag Riso Status Fehler
Nr Watt (Wh/Wp) Watt (Wh/Wp) Watt (Wh/Wp) Watt (Wh/Wp) AC / DC Wh Wp Wp Wp kWh/kWp kOhm #8 #60
WR-01 2.603 ( 0,70 ) 1.239 ( 0,67 ) -4 % 3.842 ( 0,69 ) 3.784 ( 0,68 ) 98.49 % 15.521 5.550 3.700 1.850 2,80 -4=MPP -
WR-02 2.630 ( 0,71 ) 1.236 ( 0,67 ) -6 % 3.866 ( 0,70 ) 3.803 ( 0,69 ) 98.37 % 15.610 5.550 3.700 1.850 2,81 -4=MPP -
SUMME 5.233 ( 0,71 ) 2.475 ( 0,67 ) 7.708 ( 0,69 ) 7.587 ( 0,68 ) 98.43 % 31.131 11.100 7.400 3.700 2,80 Riso - -

PV-Freckenfeld --- '25-07-01/13:10:03' --- WR_Beschreibung / SN
#1#2#3#4#5#6#7
WR WR SerienNr=SN WR Eingang-A Eingang-B Summe
Nr Typ Nummer Name Wp Wp Wp
WR-01 WR4_5TL-20 2100159998 WR-1 String-1-1=3.700 String-1-2=1.850 5.550 Wp
WR-02 WR4_5TL-20 2100160988 WR-2 String-2-1=3.700 String-2-2=1.850 5.550 Wp
SUMME
Sum-Wp 7.400 Wp 3.700 Wp 11.100 Wp

--- Tabelle für 'SMA'-Wechselrichter
SolarLog-Status-Tabelle ( #8 Werte)
0='Undetermined'
1='NoConnection'
2='Online'
3='Msg'
4='MPP'
5='Fault'
6='Warning'
7='Off'
8='Unknown'

--- Tabelle für 'SMA'-Wechselrichter
SolarLog-Fehler-Tabelle ( #60 Werte)
1='Frequency not permitted'
2='Derating occurred'
3='Unstable operation'
4='Data storage not possible'
5='Insulation resistance'
6='Grid failure'
7='-------'
8='Communication disturbed'
9='DC overcurrent'
10='Overload'
11='Overtemperature'
12='Varistor defective'
13='Start conditions not met'
14='PE connection missing'
15='L / N swapped'
16='DC overvoltage'
17='Interference of device'
18='Check fuse'
19='Check generator'
20='Disconnect generator'
21='Check parameter'
22='Check connection'
23='High discharge current'
24='SD card defective'
25='Parameter file error'
26='Set parameter'
27='Parameter setting failed'
28='Parameters set successfully'
29='No new update on the SD card'
30='Update file defective'
31='Update file OK'
32='No update file found'
33='Self diagnosis'
34='self-test'
35='Abort self-test'
36='Input A defective'
37='Input B defective'
38='Grid parameter unchanged'
39='Grid parameter locked'
40='Installer code invalid'
41='Sens. fault fan permanently on'
42='Installer code valid'
43='Update Bluetooth'
44='Update Bluetooth failed'
45='SD card is read'
46='Update completed'
47='Update main CPU'
48='Update main CPU failed'
49='Update RS485I module'
50='Update RS485I module failed'
51='Update communication'
52='Update language table'
53='Update language table failed'
54='Update display'
55='Update display failed'
56='Wait for DC start conditions'
57='Waiting for grid voltage'
58='Residual current too high'
59='Installation fault'
60='Change grid param. impossible'