| PV-Anlage --- Waldalgesheim --- 28,660 kWp --- Stand 08.11.25-21:34:00 | ||
|---|---|---|
| aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
| PV-Monitoring --- (c) pvmoni --- V1.75 2025-08-19 days_htm.php | ||
| Erstellt am 08.11.25-21:35 | - Files='days.js + base_vars.js + min_cur.js' - | |
| #56 --- PV-Waldalgesheim --- '25-11-08/21:34:00' --- Übersicht Datenlogger SMA | |||||
| PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
| Waldalgesheim | 25-11-08/21:34:00 | SMA-WebBox | xxx150022412 | 1.53 - | 93 ... 96 ... 98 % |
| Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
| 49.21 | 0 | 0 | 0 | - | - |
| PV-Waldalgesheim --- '25-11-08/21:34:00' --- aktuelle Wechselrichter-Werte ---Datum---'25_11_08/21:35:53'--- | ||||||||||||||||||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | #15 | #16 | #17 | #18 | #19 | ||||
| WR | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | Ertrag | Riso | Status | Fehler | Total (vom WR) | Total-vTag | Total-12.24 | 2025 | 2025 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||||
| Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | kWh/kWp | kOhm | #9 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||||
| WR-01 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 2.704 | 6.240 | 0,43 | 0 | ? | ??? | 9.213.701 | 9.210.997 | 3.214 | 119.291 | 19.117 | 113.291 | 122.505 | 19.632 | -0.3 % | -408 kWh | -65 kWh/kWp | ||||
| WR-02 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 1.468 | 3.510 | 0,42 | 0 | ? | ??? | 29.154.811 | 29.153.343 | 25.713 | 3.441 | 980 | 39.243 | 68.398 | 19.487 | -1.1 % | -741 kWh | -211 kWh/kWp | ||||
| WR-03 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 2.665 | 6.240 | 0,43 | 0 | ? | ??? | 6.234.074 | 6.231.409 | 81 | 6.153 | 986 | 0 | 6.234 | 999 | -94.9 % | -116.677 kWh | -18698 kWh/kWp | ||||
| WR-04 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 1.288 | 3.210 | 0,40 | 0 | ? | ??? | 26.140.634 | 26.139.346 | 23.098 | 3.043 | 948 | 35.336 | 61.476 | 19.151 | -2.8 % | -1.753 kWh | -546 kWh/kWp | ||||
| WR-05 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 2.624 | 6.240 | 0,42 | 0 | ? | ??? | 47.715.363 | 47.712.739 | 41.577 | 6.139 | 984 | 74.372 | 122.087 | 19.565 | -0.7 % | -826 kWh | -132 kWh/kWp | ||||
| WR-06 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 1.588 | 3.510 | 0,45 | 0 | ? | ??? | 69.138.778 | 69.137.190 | 65.671 | 3.467 | 988 | 0 | 69.139 | 19.698 | bester WR mit 100% | ||||
| SUMME | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 12.337 | 28.950 | 0,43 | Riso | - | - | 187.597.361 | 187.585.024 | 159.355 | 141.534 | 4.889 | 262.241 | 449.839 | 15.538 | Summe 120.405 kWh | ||||
| PV-Waldalgesheim --- '25-11-08/21:34:00' --- WR_Beschreibung / SN | ||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 |
| WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
| Nr | Typ | Nummer | Name | Wp | Wp | Wp |
| WR-01 | SMA-5000A | WR5KA-15:2007413241 | WR-1 | S1=6.240 | - | 6.240 Wp |
| WR-02 | SMA-3000A | WR30-040:2002093599 | WR-2 | S1=3.510 | - | 3.510 Wp |
| WR-03 | SMA-5000A | WR5KA-15:2000179783 | WR-3 | S1=6.240 | - | 6.240 Wp |
| WR-04 | SMA-3000A | WR30-040:2002093709 | WR-4 | S1=3.210 | - | 3.210 Wp |
| WR-05 | SMA-5000A | WR5KA-15:2000486432 | WR-5 | S1=6.240 | - | 6.240 Wp |
| WR-06 | SMA-3000A | WR30-031:2000190695 | WR-6 | S1=3.510 | - | 3.510 Wp |
| SUMME | ||||||
| Sum-Wp | 28.950 Wp | - | 28.950 Wp | |||
| --- Tabelle für 'SMA'-Wechselrichter |
| SolarLog-Status-Tabelle ( #9 Werte) |
| 0='Undetermined' |
| 1='NoConnection' |
| 2='Online' |
| 3='Msg' |
| 4='Mpp' |
| 5='Stoer.' |
| 6='Warning' |
| 7='Off' |
| 8='Unknown' |
| 9='Mpp-Peak' |
| --- Tabelle für 'SMA'-Wechselrichter |
| SolarLog-Fehler-Tabelle ( #60 Werte) |
| 1='Frequency not permitted' |
| 2='Derating occurred' |
| 3='Unstable operation' |
| 4='Data storage not possible' |
| 5='Insulation resistance' |
| 6='Grid failure' |
| 7='-------' |
| 8='Communication disturbed' |
| 9='DC overcurrent' |
| 10='Overload' |
| 11='Overtemperature' |
| 12='Varistor defective' |
| 13='Start conditions not met' |
| 14='PE connection missing' |
| 15='L / N swapped' |
| 16='DC overvoltage' |
| 17='Interference of device' |
| 18='Check fuse' |
| 19='Check generator' |
| 20='Disconnect generator' |
| 21='Check parameter' |
| 22='Check connection' |
| 23='High discharge current' |
| 24='SD card defective' |
| 25='Parameter file error' |
| 26='Set parameter' |
| 27='Parameter setting failed' |
| 28='Parameters set successfully' |
| 29='No new update on the SD card' |
| 30='Update file defective' |
| 31='Update file OK' |
| 32='No update file found' |
| 33='Self diagnosis' |
| 34='self-test' |
| 35='Abort self-test' |
| 36='Input A defective' |
| 37='Input B defective' |
| 38='Grid parameter unchanged' |
| 39='Grid parameter locked' |
| 40='Installer code invalid' |
| 41='Sens. fault fan permanently on' |
| 42='Installer code valid' |
| 43='Update Bluetooth' |
| 44='Update Bluetooth failed' |
| 45='SD card is read' |
| 46='Update completed' |
| 47='Update main CPU' |
| 48='Update main CPU failed' |
| 49='Update RS485I module' |
| 50='Update RS485I module failed' |
| 51='Update communication' |
| 52='Update language table' |
| 53='Update language table failed' |
| 54='Update display' |
| 55='Update display failed' |
| 56='Wait for DC start conditions' |
| 57='Waiting for grid voltage' |
| 58='Residual current too high' |
| 59='Installation fault' |
| 60='Change grid param. impossible' |