PV-Anlage --- Waldalgesheim --- 28,660 kWp --- Stand 17.10.25-22:49:00 | ||
---|---|---|
aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
PV-Monitoring --- (c) pvmoni --- V1.75 2025-08-19 days_htm.php | ||
Erstellt am 17.10.25-22:50 | - Files='days.js + base_vars.js + min_cur.js' - |
#52 --- PV-Waldalgesheim --- '25-10-17/22:49:00' --- Übersicht Datenlogger SMA | |||||
PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
Waldalgesheim | 25-10-17/22:49:00 | SMA-WebBox | xxx150022412 | 1.53 - | 93 ... 96 ... 98 % |
Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
49.21 | 0 | 0 | 0 | - | - |
PV-Waldalgesheim --- '25-10-17/22:49:00' --- aktuelle Wechselrichter-Werte ---Datum---'25_10_17/22:50:21'--- | ||||||||||||||||||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | #15 | #16 | #17 | #18 | #19 | ||||
WR | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | Ertrag | Riso | Status | Fehler | Total (vom WR) | Total-vTag | Total-12.24 | 2025 | 2025 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||||
Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | kWh/kWp | kOhm | #9 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||||
WR-01 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 5.298 | 6.240 | 0,85 | 0 | ? | ??? | 9.009.959 | 9.004.661 | 3.214 | 119.087 | 19.084 | 113.291 | 122.301 | 19.600 | -0.3 % | -411 kWh | -65 kWh/kWp | ||||
WR-02 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 2.881 | 3.510 | 0,82 | 0 | ? | ??? | 29.046.015 | 29.043.134 | 25.713 | 3.333 | 949 | 39.243 | 68.289 | 19.456 | -1.1 % | -737 kWh | -209 kWh/kWp | ||||
WR-03 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 5.168 | 6.240 | 0,83 | 0 | ? | ??? | 6.037.829 | 6.032.661 | 81 | 5.957 | 955 | 0 | 6.038 | 968 | -95.1 % | -116.658 kWh | -18697 kWh/kWp | ||||
WR-04 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 2.526 | 3.210 | 0,79 | 0 | ? | ??? | 26.044.926 | 26.042.400 | 23.098 | 2.947 | 918 | 35.336 | 61.381 | 19.122 | -2.8 % | -1.745 kWh | -543 kWh/kWp | ||||
WR-05 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 5.073 | 6.240 | 0,81 | 0 | ? | ??? | 47.519.327 | 47.514.254 | 41.577 | 5.943 | 952 | 74.372 | 121.891 | 19.534 | -0.7 % | -821 kWh | -131 kWh/kWp | ||||
WR-06 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 3.003 | 3.510 | 0,86 | 0 | ? | ??? | 69.025.882 | 69.022.879 | 65.671 | 3.355 | 956 | 0 | 69.026 | 19.665 | bester WR mit 100% | ||||
SUMME | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 23.949 | 28.950 | 0,83 | Riso | - | - | 186.683.938 | 186.659.989 | 159.355 | 140.620 | 4.857 | 262.241 | 448.925 | 15.507 | Summe 120.372 kWh |
PV-Waldalgesheim --- '25-10-17/22:49:00' --- WR_Beschreibung / SN | ||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 |
WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
Nr | Typ | Nummer | Name | Wp | Wp | Wp |
WR-01 | SMA-5000A | WR5KA-15:2007413241 | WR-1 | S1=6.240 | - | 6.240 Wp |
WR-02 | SMA-3000A | WR30-040:2002093599 | WR-2 | S1=3.510 | - | 3.510 Wp |
WR-03 | SMA-5000A | WR5KA-15:2000179783 | WR-3 | S1=6.240 | - | 6.240 Wp |
WR-04 | SMA-3000A | WR30-040:2002093709 | WR-4 | S1=3.210 | - | 3.210 Wp |
WR-05 | SMA-5000A | WR5KA-15:2000486432 | WR-5 | S1=6.240 | - | 6.240 Wp |
WR-06 | SMA-3000A | WR30-031:2000190695 | WR-6 | S1=3.510 | - | 3.510 Wp |
SUMME | ||||||
Sum-Wp | 28.950 Wp | - | 28.950 Wp |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Status-Tabelle ( #9 Werte) |
0='Undetermined' |
1='NoConnection' |
2='Online' |
3='Msg' |
4='Mpp' |
5='Stoer.' |
6='Warning' |
7='Off' |
8='Unknown' |
9='Mpp-Peak' |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Fehler-Tabelle ( #60 Werte) |
1='Frequency not permitted' |
2='Derating occurred' |
3='Unstable operation' |
4='Data storage not possible' |
5='Insulation resistance' |
6='Grid failure' |
7='-------' |
8='Communication disturbed' |
9='DC overcurrent' |
10='Overload' |
11='Overtemperature' |
12='Varistor defective' |
13='Start conditions not met' |
14='PE connection missing' |
15='L / N swapped' |
16='DC overvoltage' |
17='Interference of device' |
18='Check fuse' |
19='Check generator' |
20='Disconnect generator' |
21='Check parameter' |
22='Check connection' |
23='High discharge current' |
24='SD card defective' |
25='Parameter file error' |
26='Set parameter' |
27='Parameter setting failed' |
28='Parameters set successfully' |
29='No new update on the SD card' |
30='Update file defective' |
31='Update file OK' |
32='No update file found' |
33='Self diagnosis' |
34='self-test' |
35='Abort self-test' |
36='Input A defective' |
37='Input B defective' |
38='Grid parameter unchanged' |
39='Grid parameter locked' |
40='Installer code invalid' |
41='Sens. fault fan permanently on' |
42='Installer code valid' |
43='Update Bluetooth' |
44='Update Bluetooth failed' |
45='SD card is read' |
46='Update completed' |
47='Update main CPU' |
48='Update main CPU failed' |
49='Update RS485I module' |
50='Update RS485I module failed' |
51='Update communication' |
52='Update language table' |
53='Update language table failed' |
54='Update display' |
55='Update display failed' |
56='Wait for DC start conditions' |
57='Waiting for grid voltage' |
58='Residual current too high' |
59='Installation fault' |
60='Change grid param. impossible' |