PV-Anlage --- Waldalgesheim --- 28,660 kWp --- Stand 21.12.24-17:00:00 | ||
---|---|---|
aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
PV-Monitoring --- (c) pvmoni --- V1.74 2024-06-20 days_htm.php | ||
Erstellt am 21.12.24-17:01 | - Files='days.js + base_vars.js + min_cur.js' - |
#27 --- PV-Waldalgesheim --- '24-12-21/17:00:00' --- Übersicht Datenlogger SMA | |||||
PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
Waldalgesheim | 24-12-21/17:00:00 | SMA-WebBox | xxx150022412 | 1.53 - | 93 ... 96 ... 98 % |
Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
49.21 | 0 | 0 | 0 | - | - |
PV-Waldalgesheim --- '24-12-21/17:00:00' --- aktuelle Wechselrichter-Werte ---Datum---'24_12_21/17:01:13'--- | ||||||||||||||||||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | #15 | #16 | #17 | #18 | #19 | ||||
WR | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | Ertrag | Riso | Status | Fehler | Total (vom WR) | Total-vTag | Total-12.23 | 2024 | 2024 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||||
Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | kWh/kWp | kOhm | #9 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||||
WR-01 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 1.477 | 6.240 | 0,24 | 0 | ? | ??? | 3.176.571 | 3.175.094 | 111.195 | 5.273 | 845 | 113.291 | 116.468 | 18.665 | -0.2 % | -241 kWh | -38 kWh/kWp | ||||
WR-02 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 863 | 3.510 | 0,25 | 0 | ? | ??? | 25.692.107 | 25.691.244 | 22.471 | 3.221 | 918 | 39.243 | 64.935 | 18.500 | -1.1 % | -714 kWh | -203 kWh/kWp | ||||
WR-03 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 1.526 | 6.240 | 0,24 | 0 | ? | ??? | 43.052 | 41.526 | 111.230 | -111.187 | -17818,41 | 0 | 43 | 6,90 | -100.0 % | -116.525 kWh | -18696 kWh/kWp | ||||
WR-04 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 760 | 3.210 | 0,24 | 0 | ? | ??? | 23.079.322 | 23.078.562 | 20.230 | 2.850 | 888 | 35.336 | 58.415 | 18.198 | -2.7 % | -1.622 kWh | -505 kWh/kWp | ||||
WR-05 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 1.487 | 6.240 | 0,24 | 0 | ? | ??? | 41.538.457 | 41.536.970 | 35.815 | 5.724 | 917 | 74.372 | 115.910 | 18.575 | -0.7 % | -798 kWh | -128 kWh/kWp | ||||
WR-06 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 934 | 3.510 | 0,27 | 0 | ? | ??? | 65.649.007 | 65.648.073 | 62.391 | 3.258 | 928 | 0 | 65.649 | 18.703 | bester WR mit 100% | ||||
SUMME | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 7.047 | 28.950 | 0,24 | Riso | - | - | 159.178.516 | 159.171.469 | 363.332 | -90.862 | -3138,59 | 262.241 | 421.420 | 14.557 | Summe 119.900 kWh |
PV-Waldalgesheim --- '24-12-21/17:00:00' --- WR_Beschreibung / SN | ||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 |
WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
Nr | Typ | Nummer | Name | Wp | Wp | Wp |
WR-01 | SMA-5000A | WR5KA-15:2007413241 | WR-1 | S1=6.240 | - | 6.240 Wp |
WR-02 | SMA-3000A | WR30-040:2002093599 | WR-2 | S1=3.510 | - | 3.510 Wp |
WR-03 | SMA-5000A | WR5KA-15:2000179783 | WR-3 | S1=6.240 | - | 6.240 Wp |
WR-04 | SMA-3000A | WR30-040:2002093709 | WR-4 | S1=3.210 | - | 3.210 Wp |
WR-05 | SMA-5000A | WR5KA-15:2000486432 | WR-5 | S1=6.240 | - | 6.240 Wp |
WR-06 | SMA-3000A | WR30-031:2000190695 | WR-6 | S1=3.510 | - | 3.510 Wp |
SUMME | ||||||
Sum-Wp | 28.950 Wp | - | 28.950 Wp |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Status-Tabelle ( #9 Werte) |
0='Undetermined' |
1='NoConnection' |
2='Online' |
3='Msg' |
4='Mpp' |
5='Stoer.' |
6='Warning' |
7='Off' |
8='Unknown' |
9='Mpp-Peak' |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Fehler-Tabelle ( #60 Werte) |
1='Frequency not permitted' |
2='Derating occurred' |
3='Unstable operation' |
4='Data storage not possible' |
5='Insulation resistance' |
6='Grid failure' |
7='-------' |
8='Communication disturbed' |
9='DC overcurrent' |
10='Overload' |
11='Overtemperature' |
12='Varistor defective' |
13='Start conditions not met' |
14='PE connection missing' |
15='L / N swapped' |
16='DC overvoltage' |
17='Interference of device' |
18='Check fuse' |
19='Check generator' |
20='Disconnect generator' |
21='Check parameter' |
22='Check connection' |
23='High discharge current' |
24='SD card defective' |
25='Parameter file error' |
26='Set parameter' |
27='Parameter setting failed' |
28='Parameters set successfully' |
29='No new update on the SD card' |
30='Update file defective' |
31='Update file OK' |
32='No update file found' |
33='Self diagnosis' |
34='self-test' |
35='Abort self-test' |
36='Input A defective' |
37='Input B defective' |
38='Grid parameter unchanged' |
39='Grid parameter locked' |
40='Installer code invalid' |
41='Sens. fault fan permanently on' |
42='Installer code valid' |
43='Update Bluetooth' |
44='Update Bluetooth failed' |
45='SD card is read' |
46='Update completed' |
47='Update main CPU' |
48='Update main CPU failed' |
49='Update RS485I module' |
50='Update RS485I module failed' |
51='Update communication' |
52='Update language table' |
53='Update language table failed' |
54='Update display' |
55='Update display failed' |
56='Wait for DC start conditions' |
57='Waiting for grid voltage' |
58='Residual current too high' |
59='Installation fault' |
60='Change grid param. impossible' |