PV-Anlage --- Winden127 --- 127,400 kWp --- Stand 31.08.25-22:45:00 | ||
---|---|---|
aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
PV-Monitoring --- (c) pvmoni --- V1.75 2025-08-19 days_htm.php | ||
Erstellt am 31.08.25-22:50 | - Files='days.js + base_vars.js + min_cur.js' - |
#53 --- PV-Winden127 --- '25-08-31/22:45:00' --- Übersicht Datenlogger SMA | |||||
PV-Anlage | Datum | SMA | SerienNr | Firmware | Wirkungsgrad AC / DC |
Winden127 | 25-08-31/22:45:00 | SMA-WebBox | 150069360 | 1.53 - | 93 ... 96 ... 98 % |
Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
27.35 | 0 | 0 | 0 | 0 | - |
PV-Winden127 --- '25-08-31/22:45:00' --- aktuelle Wechselrichter-Werte ---Datum---'25_08_31/22:50:49'--- | ||||||||||||||||||||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | #11 | #12 | #13 | #14 | #15 | #16 | #17 | #18 | #19 | #20 | #21 | #22 | #23 | ||
WR | DC-A | DC-B | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | DC-A | DC-B | Ertrag | Riso | Status | Fehler | Total (vom WR) | Total-vTag | Total-12.24 | 2025 | 2025 | Offset | GesamtX | GesamtX | Minderertrag seit Beginn | ||
Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | Wp | Wp | kWh/kWp | kOhm | #8 | #60 | Wh | Wh | kWh | kWh | kWh/kWp | kWh | kWh | kWh/kWp | % | kWh | kWh/kWp | ||
WR-01 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 38.720 | 19.760 | 14.820 | 4.940 | 1,96 | 0 | ? | - | 156.698.987 | 156.660.267 | 148.726 | 7.973 | 403,5 | 0 | 156.699 | 7.930 | -2.5 % | -4.009 kWh | -202 kWh/kWp | ||
WR-02 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 40.417 | 19.760 | 14.820 | 4.940 | 2,05 | 0 | ? | - | 156.278.747 | 156.238.330 | 147.938 | 8.341 | 422,1 | 0 | 156.279 | 7.909 | -2.8 % | -4.430 kWh | -224 kWh/kWp | ||
WR-03 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 39.555 | 19.760 | 14.820 | 4.940 | 2,00 | 0 | ? | - | 159.585.184 | 159.545.629 | 151.445 | 8.140 | 411,9 | 0 | 159.585 | 8.076 | -0.7 % | -1.123 kWh | -56 kWh/kWp | ||
WR-04 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 38.964 | 19.760 | 14.820 | 4.940 | 1,97 | 0 | ? | - | 156.445.352 | 156.406.388 | 148.521 | 7.924 | 401,0 | 0 | 156.445 | 7.917 | -2.7 % | -4.263 kWh | -215 kWh/kWp | ||
WR-05 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 40.622 | 19.760 | 14.820 | 4.940 | 2,06 | 0 | ? | - | 3.676.969 | 3.636.347 | 86.545 | -82.868 | -4193,72 | 0 | 3.677 | 186,1 | -97.7 % | -156.990 kWh | -7946 kWh/kWp | ||
WR-06 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 39.754 | 19.760 | 14.820 | 4.940 | 2,01 | 0 | ? | - | 160.708.982 | 160.669.228 | 152.545 | 8.164 | 413,2 | 0 | 160.709 | 8.133 | bester WR mit 100% | ||
WR-07 | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 0 | 8.840 | 4.420 | 4.420 | 0,00 | 0 | 0 | 0 | 0 | 0 | 0,00 | 0 | 0 | 0,00 | -100.0 % | -0 kWh | -8133 kWh/kWp | ||||
SUMME | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0 ( 0,00 ) | 0,0 % | 238.032 | 127.400 | 93.340 | 34.060 | 1,87 | Riso | - | - | 793.394.221 | 793.156.189 | 835.720 | -42.326 | -332,23 | 0 | 793.394 | 6.228 | Summe 170.815 kWh |
PV-Winden127 --- '25-08-31/22:45:00' --- WR_Beschreibung / SN | ||||||
#1 | #2 | #3 | #4 | #5 | #6 | #7 |
WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
Nr | Typ | Nummer | Name | Wp | Wp | Wp |
WR-01 | SMA-TP-17000TL | WR11TL08:2000783687 | WR-1 | S1=14.820 | S2=4.940 | 19.760 Wp |
WR-02 | SMA-TP-17000TL | WR11TL09:2000943168 | WR-2 | S1=14.820 | S2=4.940 | 19.760 Wp |
WR-03 | SMA-TP-17000TL | WR11TL08:2000781246 | WR-3 | S1=14.820 | S2=4.940 | 19.760 Wp |
WR-04 | SMA-TP-17000TL | WR11TL08:2000780947 | WR-4 | S1=14.820 | S2=4.940 | 19.760 Wp |
WR-05 | SMA-TP-17000TL | WR11TL08:2001180813 | WR-5 | S1=14.820 | S2=4.940 | 19.760 Wp |
WR-06 | SMA-TP-17000TL | WR11TL08:2000798925 | WR-6 | S1=14.820 | S2=4.940 | 19.760 Wp |
WR-07 | SMA-TP-8000TL | WR-7 | S1=4.420 | S2=4.420 | 8.840 Wp | |
SUMME | ||||||
Sum-Wp | 93.340 Wp | 34.060 Wp | 127.400 Wp |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Status-Tabelle ( #8 Werte) |
0='Undetermined' |
1='NoConnection' |
2='Online' |
3='Msg' |
4='MPP' |
5='Fault' |
6='Warning' |
7='Off' |
8='Unknown' |
--- Tabelle für 'SMA'-Wechselrichter |
SolarLog-Fehler-Tabelle ( #60 Werte) |
1='Frequency not permitted' |
2='Derating occurred' |
3='Unstable operation' |
4='Data storage not possible' |
5='Insulation resistance' |
6='Grid failure' |
7='-------' |
8='Communication disturbed' |
9='DC overcurrent' |
10='Overload' |
11='Overtemperature' |
12='Varistor defective' |
13='Start conditions not met' |
14='PE connection missing' |
15='L / N swapped' |
16='DC overvoltage' |
17='Interference of device' |
18='Check fuse' |
19='Check generator' |
20='Disconnect generator' |
21='Check parameter' |
22='Check connection' |
23='High discharge current' |
24='SD card defective' |
25='Parameter file error' |
26='Set parameter' |
27='Parameter setting failed' |
28='Parameters set successfully' |
29='No new update on the SD card' |
30='Update file defective' |
31='Update file OK' |
32='No update file found' |
33='Self diagnosis' |
34='self-test' |
35='Abort self-test' |
36='Input A defective' |
37='Input B defective' |
38='Grid parameter unchanged' |
39='Grid parameter locked' |
40='Installer code invalid' |
41='Sens. fault fan permanently on' |
42='Installer code valid' |
43='Update Bluetooth' |
44='Update Bluetooth failed' |
45='SD card is read' |
46='Update completed' |
47='Update main CPU' |
48='Update main CPU failed' |
49='Update RS485I module' |
50='Update RS485I module failed' |
51='Update communication' |
52='Update language table' |
53='Update language table failed' |
54='Update display' |
55='Update display failed' |
56='Wait for DC start conditions' |
57='Waiting for grid voltage' |
58='Residual current too high' |
59='Installation fault' |
60='Change grid param. impossible' |